PlanLumens, lux, and watts are three different questions
Brightness, light on a surface, and energy use belong in separate columns. Once they are separated, a lighting plan becomes much easier to read.
Plan · Brightness
Turn room dimensions and an adjustable target illuminance into a transparent lumen range and fixture count.
Centered on 6,370 design lumens after the declared factors.
Sketch only. Confirm fixture photometry, reflectance, glare, daylight, controls, and local requirements.
From number to decision
A 16 × 12 ft room at 200 lux, with 0.70 utilization and 0.80 maintenance, produces a design estimate of roughly 6,370 lumens before fixture selection.
The visible method
LimitA simplified lumen-method estimate cannot model fixture photometry, surface reflectance, daylight, glare, or local code.
Results are computed from the fields you enter. Glow & Gauge does not infer a product, electricity rate, room reflectance, or professional approval.